INSTALLATION INSTRUCTIONS
WALL MOUNTED
PACKAGE AIR CONDITIONERS
MODELS
WL423
WL484
WL602
Manual : 2100-400
Supersedes:
File: Volume III Tab 16
Date: 01-31-02
Bard Manufacturing Company
Bryan, Ohio 43506
Since 1914...Moving ahead just as planned.
© Copyright 2002
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - Bryan, Ohio 43506

INSTALLATION INSTRUCTIONSWALL MOUNTEDPACKAGE AIR CONDITIONERSMODELSWL423WL484WL602Manual : 2100-400Supersedes:File: Volume III Tab 16Date: 01-31-02B

Strany 2 - CONTENTS

Manual 2100-400Page 8FIGURE 3MOUNTING INSTRUCTIONSMIS-947

Strany 3 - Page 1

Manual 2100-400Page 9 WARNINGA minimum of 1/4 inch clearance must be maintained betweenthe supply air duct and combustible materials. Th

Strany 4 - ELECTRIC HEAT TABLE

Manual 2100-400Page 10FIGURE 5WALL MOUNTING INSTRUCTIONSFIGURE 6WALL MOUNTING INSTRUCTIONSMIS-1051SEE FIGURE 3 – MOUNTING INSTRUCTIONSSUPPLY AIR

Strany 5 - BACK VIEW

Manual 2100-400Page 11FIGURE 7COMMON WALL MOUNTING INSTALLATIONSFREE AIR FLOW NO DUCTDUCTED SUPPLY RETURN AT UNITFALSE WALL INSTALLATIONCLOSET

Strany 6 - ELECTRICAL SPECIFICATIONS

Manual 2100-400Page 12WIRING – MAIN POWERRefer to the unit rating plate for wire sizing informationand maximum fuse or “HACR” type circuit breake

Strany 7 - DUCT WORK

Manual 2100-400Page 13FIGURE 8UNIT 24V TERMINAL BOARDMIS-1373A

Strany 8 - CONDENSATE DRAIN

Manual 2100-400Page 14THREE PHASE SCROLL COMPRESSORSTART UP INFORMATIONScroll compressors, like several other types ofcompressors, will only compre

Strany 9 - WARNING

Manual 2100-400Page 15COMPRESSOR CONTROL MODULEThe compressor control module is standard on theWL484 and WL602 models covered by this manual andi

Strany 10 - MOUNTING INSTRUCTIONS

Manual 2100-400Page 16REMOVAL OF FAN SHROUD1. Disconnect all power to the unit.2. Remove the screws holding both grilles, one on eachside of unit,

Strany 11 - WARNING

Manual 2100-400Page 17TABLE 8RECOMMENDED AIRFLOW* Rated CFM and ESP on high speed tap.ledoMdetaR*MFCdetaR*PSEdednemmoceRegnaRwolfriA324LW004103

Strany 12 - FIGURE 6

FiguresFigure 1 Unit Dimensions ... 3Figure 2 Fresh Air Damper Assembly ... 6Figure 3 Mounting Inst

Strany 13 - MIS-1050

Manual 2100-400Page 18TABLE 11OPTIONAL ACCESSORIESWL423-AWL423-BWL423-CWL484-AWL484-BWL484-CWL602-AWL602-BWL602-CtraPrebmuNnoitpircseD5-POB5-DAFB5

Strany 14 - WIRING – LOW VOLTAGE WIRING

Manual 2100-400Page 1Getting Other Information and PublicationsThese publications can help you install the airconditioner or heat pump. You can u

Strany 15 - MIS-1373A

Manual 2100-400Page 2WALL MOUNT GENERAL INFORMATIONHEAT PUMP WALL MOUNT MODEL NOMENCLATUREWL 42 3 – A 10 X N X X X

Strany 16 - START UP

Manual 2100-400Page 3FIGURE 1UNIT DIMENSIONSMIS-1286ledoMhtdiW)W(htpeD)D(-gieHth)H(ylppuSnruteREFG I JKLMNOPQRSTABCB24LW84LW06LW570.24234.22578.

Strany 17 - PRESSURE SERVICE PORTS

Manual 2100-400Page 4Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.Based on 75° C copp

Strany 18 - TROUBLESHOOTING

Manual 2100-400Page 5SHIPPING DAMAGEUpon receipt of equipment, the carton should bechecked for external signs of shipping damage. Ifdamage is fo

Strany 19

Manual 2100-400Page 6FRESH AIR INTAKEAll units are built with fresh air inlet slots punched inthe service panel.If the unit is equipped with a fres

Strany 20 - OPTIONAL ACCESSORIES

Manual 2100-400Page 7INSTALLATION INSTRUCTIONS WARNINGFailure to provide the 1/4 inch clearancebetween the supply duct and a combustiblesu